Glass Thickness Requirements AS1288
Selecting the right glass thickness is critical for safety and compliance in Australian building projects. Our Glass Thickness Calculator , tailored to AS1288 Australian Standards, provides a straightforward solution for this. It guides you in choosing the correct glass thickness for various applications, ensuring each installation meets essential safety standards and regulatory requirements.
Glass Thickness Calculator
Select Application: Choose the specific application for which you need to determine the glass thickness.
Enter Maximum Dimension: Input the maximum dimension of the glass panel in square meters (m²).
Calculate: Click the ‘Calculate’ button to obtain the recommended glass thickness for your selected application.
TABLE 5.1: MAXIMUM AREAS OF SAFETY GLASS
Area m² | Laminated Glass Thickness | Toughened & Toughened Laminate Glass Thickness | Safety Organic-coated Glass (vinyl back) Thickness |
---|---|---|---|
2.2 | 5mm | 4mm | 4mm |
3.0 | 6mm | 5mm | 5mm |
5.0 | 8mm | 6mm | 6mm |
7.0 | 10mm | 8mm | Grade B Safety Glass (Wired Glass) |
9.0 | 12mm | 10mm | 6mm |
NOTE: TOUGHENED LAMINATE CAN BE SUBSTITUTED WHERE TOUGHENED IS REQUIRED